Promega's Política de cookies

Empleamos cookies y tecnologías similares para mantener la funcionalidad de nuestro sitio web, analizar su rendimiento, mejorar el funcionamiento y mostrar contenido personalizado. Algunas cookies son esenciales para el buen funcionamiento de nuestro sitio web. El resto no serán instaladas en su equipo sin su consentimiento. Visite la Política de Cookies para obtener mayor detalle.

glomaxgalaxyheader

Proven GloMax® Galaxy Bioluminescence Imaging Applications

From protein interactions to cell killing assays, the GloMax® Galaxy Bioluminescence Imager* brings your NanoLuc-based experiments to life.

Browse our validated applications and get inspired for your next experiment. New to Live-Cell Imaging? Get started with our live-cell imaging guide.

Protein Translocation

visualize-efgr
Visualize EGFR Internalization in Real Time

Use bioluminescence imaging to visualize HiBiT-tagged EGFR after EGF stimulation, complementing plate-based assays with single-cell spatial resolution.


Cell Model: Standard Cell Lines
Research Area: Cancer
Readout Type: Bioluminescence
View the Article

Targeted Protein Degradation

gspt1
Visualize GSPT1 Protein Degradation

Monitor HiBiT-GSPT1 degradation in HEK293 cells using bioluminescent imaging; complements plate-based assays by confirming single-cell degradation patterns.


Cell Model: Standard Cell Lines
Research Area: Cancer
Readout Type: Bioluminescence
View the Article

Protein Translocation

track-catenin
Track β-Catenin Stabilization in Live Cells

Image HiBiT assays to visualize nuclear accumulation of β-catenin following inhibitor treatment.


Cell Model: Standard Cell Lines
Research Area: Cancer
Readout Type: Bioluminescence
Read the Blog

Target Engagement 

PRMT5-MTA Complex
Image PRMT5-MTA Complex

Characterize PRMT5-MTA complex engagement in live cells using bioluminescence imaging; reinforce biochemical findings by generating insights at the single-cell level.   


Cell Model: Standard Cell Lines
Research Area: Cancer
Readout Type: Bioluminescence
View the Article

Protein:Protein Interactions

kras-craf
Visualize KRAS-CRAF Interaction Dynamics

Use NanoBRET® assays to visualize KRAS(G12D):CRAF interactions. BRET signal shifts after inhibitor treatment, confirming disruption of protein interaction and complementing plate-based analysis.


Cell Model: Standard Cell Lines
Research Area: Cancer
Readout Type: Bioluminescence
View the Article

Protein:Protein Interactions

gpcr-arrestin
Visualize GPCR-Arrestin Interaction

Visualize protein:protein interactions via NanoBiT® signal from CX3CR1–ARRB2 interaction in HEK293 cells. Imaging confirms receptor internalization and complements plate-based PPI assays.


Cell Model: Standard Cell Lines
Research Area: Immunology
Readout Type: Bioluminescence
Read the Blog

Cell Staining

pa1093-tile
Fluorescence Nuclei Staining and Co-Imaging with NanoLuc® Luciferase

Visualize nuclear staining in fixed or live cells using NucSpot® Live 488 and co-image with NanoLuc® technology on the GloMax® Galaxy Bioluminescence Imager.


Cell Model: Standard Cell Lines
Research Area: Cell Biology
Readout Type: Bioluminescence, Fluorescence
View the Protocol

Cell Staining

pa1092-tile
Far-Red Fluorescence Nuclei Staining and Co-Imaging with NanoLuc® Luciferase

Use NucSpot® Live 650 to visualize nuclei in fixed or live cells with NanoLuc® technology.


Cell Model: Standard Cell Lines
Research Area: Cell Biology
Readout Type: Bioluminescence, Fluorescence
View the Protocol

General / Compatibility Testing

pa1030-tile
Evaluate Imaging Performance with the GloMax® Galaxy Test Slide

Demonstrate brightfield, fluorescence and luminescence capabilities of the GloMax® Galaxy Bioluminescence Imager using a pre labeled, fixed HeLa test slide expressing NanoLuc®-HaloTag® reporters. Includes reagents and imaging guidance to help validate instrument performance and user workflow.


Cell Model: Standard Cell Lines
Research Area: General Imaging
Readout Type: Brightfield, Fluorescence, Bioluminescence
View the Protocol

Target Engagement

wp138-tile
Image NanoBRET® Target Engagement in Live Cells

Quantify protein:small molecule binding by imaging NanoBRET® signals on the GloMax® Galaxy. This workflow demonstrates exposure optimization, dynamic range improvement and ratiometric analysis using GPCR targets HTR2A and HTR2C in live cells.


Cell Model: Standard Cell Lines
Research Area: Drug Discovery
Readout Type: Bioluminescence
Read the White Paper

3D Model Imaging

human-neurospheres-brain-spheroids-wp143-cropped
Imaging 3D Models

Bioluminescent imaging of 3D spheroid cultures expressing NanoLuc® luciferase. This workflow includes recommendations for optimizing expression levels and imaging timing, along with a detailed example protocol for culturing and imaging spheroids.


Cell Model: 3D Cell Models (e.g., spheroids and neurospheres)
Research Area: Neuroscience, Oncology, 3D Cell Culture Imaging
Readout Type: Bioluminescence
Read the White Paper

General / Cell Staining

regular-cell-staining-image
Enhancing Luminescent Imaging with Fluorescent Staining

This guide outlines considerations and troubleshooting examples for incorporating fluorescence imaging into a luminescence imaging workflow on the GloMax® Galaxy.  


Cell Model: Standard Cell Lines
Research Area: General Imaging
Readout Type: Fluorescence
Read the White Paper

*The GloMax® Galaxy Bioluminescence Imager is for research use only.

Want to see the GloMax® Galaxy Bioluminescence Imager in action?

Explore Demo Options